Date: 09 September 2021 Release note for Star Cool controller software 0358 rev 02 The key changes that have been implemented in software version 0358_02 are listed below: 1. Alarm changes Alarm 307 Pdis high - K1 is renumbered to Alarm 308. AirEx open alarm (607) can be cleared when AirEx is closed and has been calibrated (without 15 minutes delay). A status text on the user panel will inform the user that calibration can inactive the alarm. Minor time delay in fan motor overheat alarms to prevent false alarms. 2. Prefix changes New prefix CMIU added will have StarConomy on. HMMU prefix will have StarConomy on. DAYU ranges will act as ML units Certain ranges of prefix DAYU will have StarConomy default on. ML prefix will no longer reset temperature set point after 96H off power period. 3. System improvements Missing communication to atmosphere sensors are indicated only as communication alarms and not as a defect sensor. A display text will indicate that the unit is checking communication until, and if the alarm is set. O2 sensor will not be active, when Tset < 0C (unless CA is activated – CA can be active when Tset < 0C). The automatic air ex valve is not allowed to be opened when O2 sensor is in cleaning mode. System allows vacuum pump to start if O2 is above 17 pct, allowing membrane system to actively reduce O2 from 21% Vacuum pump will now start when temperature >10°C (previously >70°C). 4. User interface changes Changes to ACT so it is now terminated if the unit power off-time rules are reached. Prefix dependent for Programs termination. Bjerndrupvej 47 • 6360 Tinglev, Denmark • CVR/SE no.: 13 82 37 74 www.mcicontainers.com • service@starcool.com • +45 7364 3400