Software Release Note 10 August 2017 Release Note for Star Cool Controller Software 0355 rev 01 The preceding software version is release 0354_15. The key changes that will be implemented in the software version 0355_01 are listed below: New functions and changes to existing functions: Periodical temp sensor checks (Ventilation mode) while running Temp sensor check added to function test (step 2100) StarConomy enabled on additional units Alarm visualization change a) Only active operations alarms are shown when pushing the alarm key b) Alarms and warnings active/inactive can only be viewed using PTI menu line 001 Status text: "Limiter Active" shown when compressor speed is reduced due to limiting from; high FC temp, high FC current, high total current, low suction pressure, high discharge pressure Datalog Averaging – to enable logging of average values of: - Evaporator fan, condenser fan, compressor speed, airex valve openings Refrigerant R-513A (aka “XP10”) compatible Important to configure the unit with the type of expansion valves fitted; R134a only, or R134a/R513A (Controller configurations menu): Valve config type: R134a/R513A Two grooves in the valve body and Vexp pointing upwards requires “R134a/R513A” as setting. ________________________________________________________________________________________________________________________ Bjerndrupvej 47 6360 Tinglev, Denmark Service Phone: +45 7364 3500 Fax: +45 7364 3569 CVR/SE no.: 13 82 37 74 service@starcool.com www.starcool.com